Skip to content
ContentLora

    Tip: press / anywhere to search.

    Explainer

    How data centres work: servers, power, cooling and efficiency

    Data centres are buildings that house servers, storage systems and networking equipment in racks organised into rows.[1] The servers do the computing and use around 60% of the electricity, while batteries and backup generators keep the site running through outages and cooling removes the heat.[2][3][4] The IEA estimates data centres used about 1.5% of the world's electricity in 2024, and projects their use roughly doubling from 485 TWh in 2025 to about 950 TWh in 2030.[5][6]

    Editor reviewedUpdated Explainer18 claims · 100% primaryComputing, Energy and climate

    This page explains how data centres work in general. For the electricity demands of AI data centres in depth, see AI data centres and power; for the services that run on them, see how cloud computing works.

    What is inside

    The International Energy Agency (IEA) describes data centres as facilities that house servers, storage systems, networking equipment and associated components, installed in racks organised into rows.[1] Servers are the computers that process and store data, using central processors and accelerators such as GPUs; on average they account for around 60% of a modern data centre’s electricity demand.[2]

    Storage systems handle centralised storage and backup and use around 5% of the electricity, while networking equipment, the switches, routers and load balancers that move traffic, uses up to 5%.[7] The IEA groups data centres into three broad types: enterprise, colocation and server provider, and hyperscale.[8] AI is changing the hardware: the IEA estimates that the power density of AI servers rose 11-fold between 2020 and 2025.[9]

    Keeping the power on

    The IEA notes that uninterruptible power supply (UPS) batteries and backup generators keep a site running during outages; they are rarely used but are needed for the very high reliability data centres must meet.[3]

    The Uptime Institute’s classification puts data centres into four progressive Tiers that set criteria for maintenance, power, cooling and fault capabilities.[10] A Tier I site has a UPS, dedicated cooling and an engine generator but must shut down completely for maintenance; a Tier III site is concurrently maintainable, so equipment can be serviced without a shutdown; and Tier IV adds fault tolerance, so a single equipment failure does not affect IT operations.[11] The Institute stresses that a Tier IV site is not simply better than a Tier II site; the levels suit different business needs.[10]

    Removing the heat

    The IEA says cooling takes about 7% of electricity in efficient hyperscale data centres and over 30% in less efficient enterprise data centres.[4] AI pushes this further: the IEA says an AI data centre must remove heat equivalent to about 30 natural gas boilers per server rack.[12]

    Measuring efficiency: PUE

    The standard efficiency measure is power usage effectiveness (PUE), which compares a site’s overhead energy, such as cooling and power distribution, with the energy used by its IT equipment.[13] A PUE of 2.0 means one extra watt of overhead for every watt of IT power, while a PUE close to 1.0 means nearly all the energy goes to computing.[13]

    Google reports an average annual PUE of 1.09 across its global fleet of data centres in 2025.[14] Citing the Uptime Institute’s 2025 survey, Google says the average PUE of the surveyed data centres worldwide was 1.54.[15]

    How much electricity they use

    The IEA estimates that data centres used around 415 TWh in 2024, about 1.5% of the world’s electricity, after growing about 12% a year since 2017.[5][16] Its April 2026 projection has their use roughly doubling from 485 TWh in 2025 to 950 TWh in 2030, about 3% of global demand.[6] The United States accounted for 45% of global data centre electricity use in 2024, China 25% and Europe 15%.[17]

    In the United States, a Lawrence Berkeley National Laboratory report for the Department of Energy found that data centres used about 4.4% of the country’s electricity in 2023 and projected 6.7% to 12% by 2028.[18]

    Next in the crash course

    Developing in AI & Computing

    Go deeper

    Questions readers ask

    What is inside a data centre?

    Servers, storage systems, networking equipment and associated components, installed in racks organised into rows, plus cooling equipment and backup power such as UPS batteries and generators.[1][3]

    What uses the most electricity in a data centre?

    Servers, which the IEA says account on average for around 60% of electricity demand in modern data centres. Storage takes around 5% and networking up to 5%, while cooling ranges from about 7% in efficient hyperscale sites to over 30% in less efficient enterprise sites.[2][7][4]

    What is PUE?

    Power usage effectiveness compares a data centre's overhead energy, such as cooling and power distribution, with the energy used by its IT equipment. A PUE of 2.0 means one extra watt of overhead for every watt of IT power; a value near 1.0 means nearly all energy goes to computing.[13]

    What do data centre Tiers mean?

    The Uptime Institute rates data centres in four progressive Tiers covering maintenance, power, cooling and fault capabilities. Tier III sites can be maintained without shutting down and Tier IV sites add fault tolerance, but the Institute says a higher Tier is not inherently better, just suited to different needs.[10][11]

    How much electricity do data centres use?

    The IEA estimates around 415 TWh in 2024, about 1.5% of global electricity, and projects roughly 950 TWh by 2030. In the United States, a Lawrence Berkeley National Laboratory report put data centres at about 4.4% of electricity use in 2023.[5][6][18]

    Sources

    · 18 claims from 4 publishers

    Each numbered claim is a statement we checked against the sources listed with it. Tap a number in the text to see its sources in place.

    1. [1]

      The IEA describes data centres as facilities that house servers, storage systems, networking equipment and associated components, installed in racks organised into rows. confirmedas of 2025-04-10

    2. [2]

      The IEA says servers are the computers that process and store data, using CPUs and accelerators such as GPUs, and account on average for around 60% of electricity demand in modern data centres. confirmedas of 2025-04-10

    3. [3]

      The IEA says uninterruptible power supply (UPS) batteries and backup generators keep data centres powered during outages; they are rarely used but needed for the very high reliability data centres must meet. confirmedas of 2025-04-10

    4. [4]

      The IEA says cooling accounts for about 7% of electricity use in efficient hyperscale data centres and over 30% in less efficient enterprise data centres. confirmedas of 2025-04-10

    5. [5]

      The IEA estimates that data centres used around 1.5% of the world's electricity in 2024, or 415 TWh. confirmedas of 2025-04-10

    6. [6]

      The IEA's April 2026 projection has data centre electricity use roughly doubling from 485 TWh in 2025 to 950 TWh in 2030, about 3% of global electricity demand. confirmedas of 2026-04-16· forecast

    7. [7]

      The IEA says storage systems account for around 5% of data centre electricity use and networking equipment, such as switches, routers and load balancers, for up to 5%. confirmedas of 2025-04-10

    8. [8]

      The IEA groups data centres into three types, enterprise, colocation and server provider, and hyperscale, all of which contribute to growth in electricity use. confirmedas of 2025-04-10

    9. [9]

      The IEA estimates that the power density of AI servers rose 11-fold between 2020 and 2025 and is set to rise a further fourfold by 2027. confirmedas of 2026-04-16

    10. [10]

      The Uptime Institute classifies data centres into four progressive Tiers that set criteria for maintenance, power, cooling and fault capabilities, and says a higher Tier is not inherently better but suits different business needs. confirmedas of 2026-11-14

    11. [11]

      Under the Uptime Institute's system, a Tier I site has a UPS, dedicated cooling and an engine generator but must shut down for maintenance; Tier III is concurrently maintainable, needing no shutdown to maintain or replace equipment; and Tier IV adds fault tolerance so an equipment failure does not affect IT operations. confirmedas of 2026-11-14

    12. [12]

      The IEA says an AI data centre must remove heat equivalent to about 30 natural gas boilers per server rack. confirmedas of 2026-04-16

    13. [13]

      Power usage effectiveness (PUE) compares a data centre's overhead energy, such as cooling and power distribution, with the energy used by its IT equipment; a PUE of 2.0 means one extra watt of overhead for every watt of IT power, and a PUE close to 1.0 means nearly all energy goes to computing. confirmedas of 2026-11-14

    14. [14]

      Google reports that its global fleet of data centres had an average annual PUE of 1.09 in 2025. confirmedas of 2025-12-31

    15. [15]

      Google, citing the Uptime Institute's 2025 Global Data Center Survey, says the global average PUE of the survey respondents' data centres was 1.54. reportedas of 2025-12-31

    16. [16]

      The IEA says global data centre electricity use grew about 12% a year from 2017 to 2024, more than four times faster than total electricity use. confirmedas of 2025-04-10

    17. [17]

      The United States accounted for 45% of global data centre electricity use in 2024, China 25% and Europe 15%, according to the IEA. confirmedas of 2025-04-10

    18. [18]

      A December 2024 Lawrence Berkeley National Laboratory report for the US Department of Energy found that data centres used about 4.4% of US electricity in 2023 and projected 6.7% to 12% by 2028. confirmedas of 2024-12-20· forecast

    Revision history (1)
    1. Page created.

    Created Nov 14, 2026. Last reviewed by an editor on Nov 14, 2026. Next scheduled review: May 14, 2027.

    Cite this page

    "How data centres work: servers, power, cooling and efficiency." ContentLora, updated Nov 14, 2026. https://contentlora.com/explain/how-data-centers-work

    Spotted an error? Suggest a correction or emailcorrections@contentlora.com.